IEC 62776 PDF

IEC DOUBLE-CAPPED LED LAMPS DESIGNED TO RETROFIT LINEAR FLUORESCENT LAMPS – SAFETY SPECIFICATIONS. IEC , First edition, *) – Double-capped LED lamps Corrigendum, March till IEC är inarbetat i standarden. Buy IEC Ed. Double-capped LED lamps designed to retrofit linear fluorescent lamps – Safety specifications from SAI Global.

Author: Dousar Maudal
Country: Nicaragua
Language: English (Spanish)
Genre: Relationship
Published (Last): 12 May 2007
Pages: 232
PDF File Size: 12.18 Mb
ePub File Size: 15.33 Mb
ISBN: 965-4-46713-119-4
Downloads: 22658
Price: Free* [*Free Regsitration Required]
Uploader: Groshakar

The marking shall be legible after the test. Free Seminar Guangzhou Important Updates! Intertek is a leading Total Quality Assurance provider to industries worldwide.

Medias this blog was made to help people to easily download or read PDF files. Labeling requirements are to power ballast lamps? Recommendations for whole product testing or batch testing are given in Annex A. It is then gradually raised to the full value. For the replacement of the tube, the LED lamp tube of the interior light of the lamp needs to be changed, which is not within the scope of this standard. NOTE 1 The rated voltage or voltage range of the lamp can from the open circuit voltage.

Dimension A is measured after the lamp is stabilised and as Aoperating.

The requirements in this standard are given for general lighting service excluding for example explosive atmospheres. Protection against accidental contact with live parts during insertion and normal operation. The requirements of this standard relate only to type testing. Figure 7 — Schematic steps of removing a fluorescent lamp and inserting a double-capped LED lamp designed to retrofit linear fluorescent lamp 5. Scope This International Standard specifies the safety and interchangeability requirements, and the exchange operation together with the test methods and conditions required to show compliance of double-capped LED lamps with G5 and G13 caps, intended for replacing fluorescent lamps with the same caps, having: In the case of doubt based on the inspection of the lamp and the examination of the lamp circuit diagram, and in agreement with the manufacturer or responsible vendor, lamps shall be specially oec so that a fault condition can be simulated and shall be submitted for testing see Clause Following IECSection 8, basic insulation during lamp insertion is sufficient.

  80186 DATASHEET PDF

Scope — this standard covers only the lamps which are: Contact us service. The requirements in this standard are given for general lighting service excluding for example explosive atmospheres.

Intertek is a leading Total Quality Assurance provider to industries worldwide. The publication of this standard gives a suitable safety guide for LED manufacturers exporting to EU market.

IEC /ISH | IEC Webstore

For lamps for other applications additional requirements may apply. The standard iex only applicable to LED lamp to meet the following conditions: Categories News 20 Achievement 6. The existing jec, into which the double-capped LED lamps are fitted, can be operated with electromagnetic or electronic controlgear. Opened lamps or inspection of internal component parts of the lamp may be required to verify conformity with Clauses 11, 12 and 14 of this standard.

C exemption working voltage not exceeding 25Vr. We provide safety, performance and energy testing service for all kinds of lighting products used for household, commercial, automobile, airports, traffic and railway, etc. Further requirements on failing safe are given in Clause Variation of dimension A due 6.

IEC 62776:2014/ISH1:2018

The length of the 62776 shall not change significantly within the specified ambient temperature range of the lamp. In cases of doubt regarding the suitability the application the manufacturer of this lamp should be consulted.

NOTE 2 This standard includes photobiological safety.

In Maygeneral safety requirements IEC If lamps are iev with a voltage range, rated voltage is taken as the maximum of 6276 voltage range marked unless the manufacturer declares another voltage as the most critical one.

  ARPEJO PARA TECLADO EM PDF

Intertek Services Intertek has lighting testing experts and state-of-the-art laboratories located in Asia, Europe and North America, helping your products to meet various national and international standards in the shortest delivery time. The main 26776 of update. Double-capped input, intended for replacing fluorescent lamps with same caps, designed for replacement without requiring any internal modification of the luminaire; G5 and G13 caps; Rated power up to W; Rated voltage up to V; Note: Such LED lamps are designed for replacement without requiring any internal modification of the luminaire.

The lamp under test shall consist of a iecc unit, operated at its rated supply voltage.

Such LED lamps are designed for replacement without requiring any internal modification of the luminaire. Example for a retrofit ie. The Ief replacement starter shall be marked as in Figure 4. No flashover or breakdown shall occur during the test.

Figure 8 — Test configuration 67276 touch current measurement. This standard does not cover double-capped conversion LED lamps where modification in the luminaire is required. Size and gauge requirements: The length of the lamp not change significantly within the specified ambient temperature range of the lamp.

The content of the instructions shall include the following. The publication of this standard gives a suitable safety guide for LED manufacturers exporting to EU market. Ice assessment project in view of the above principles, the standard mainly focuses on the evaluation of:

Author: admin